Configuration Reports : Threshold Crossing Alerts Report

Threshold Crossing Alerts Report
Threshold Crossing Alerts (TCAs) are pre-emptive, user-configurable alarms triggered when specific thresholds are crossed.
They alarm on both rising and falling threshold crossing events (i.e., floor and ceiling levels). For both levels, one value raises the alarm, while another value clears it.
ON by default:
n
Appliance Capacity - triggers when an appliance reaches 95% of its total flow capacity. It is not configurable and can only be cleared by an operator.
n
File-system utilization - percent of non-Network Memory disk space filled by the appliance. This TCA cannot be disabled.
n
Tunnel latency - measured in milliseconds, the maximum latency of a one-second sample within a 60-second span
OFF by default:
n
LAN-side receive throughput - based on a one-minute average, the LAN-side receive TOTAL for all interfaces
n
WAN-side transmit throughput - based on a one-minute average, the WAN-side transmit TOTAL for all interfaces
n
n

Please send comments or suggestions regarding user documentation to techpubs@silver-peak.com.